Color iQC-iMatch v10.8.2.9
이름 : Color iQC-iMatch
버전 : v10.8.2.9
이전 버전 : v10.8.1.3
릴리스 날짜 : 0001년 01월 01일
파일 유형 : PC - Self-extracting Installer
파일 다운로드 : PC 버전
메모:
Version v10.8.2.9 is a maintenance release that addresses the following issues:
- Ci5x and Ci6x devices do not return valid spectral data when using software to trigger reading.
- Filter issue where the label got updated but not the value.
- Unable to manually edit a formula or correction if the initial formulas were in Shots.
- Converting older collections that used lbs/gal for specific gravity were not converted properly.
- Colorant Rules are not behaving properly.
- Crash if editing a recipe when no standards are selected.
- Issue bringing in older macros.
- Copied Collection does not save letdowns with the Collection.
- When submitting to SCS, if there is a Job Template Type of Industrial/Textile or None, the CxF file will not contain all needed items.
- Temperature and Humidity data disappeared when retrieving items from the database.
- Import and conversion of IFS Collection does not bring in Alternate Dry Weight values.
- Manually editing a formula that was scaled to units of Kg for resin and g for colorants shows all values in Kg.
- E-Submit is now re-enabled but it will only create an email and attach a QTX or CxF to that email - MAPI support has been dropped by Microsoft due to security concerns.
- If you select "Create New Recipe" for the option “Correct From” in Correction mode, a “New/Edit Composition” dialog will be displayed, but you will not be able to get out of this by cancelling.
- Some XCM Two-Constant Relative Cal Sets were not getting imported and converted properly to EFX Collections.
Improvements and New features:
- Saving new strings for file locations in Scorecard Submissions and Imported Data.
- Added the ability to show only Standards in the Formulation screen.
- Auto-update of standards to the database did not get applied when more than 24 standards were in an e-Job. New registry setting for allowing more than 24.
- Allow the user to select which extended data to export.
- New setting to display an icon if the trial meets requirements for standard replacement.
- Multiple department numbers available for e-submit.
- Users can now see Pass/Fail status for multiple Illum/Obs conditions.
Important: Any e-Job saved with formulation-related information will not be backward compatible with earlier versions.
CCAutomationTool 2023.9
Build 5: General: Reintroduced preferences parameter to command line (optional).
Build 4: Automation: Add version 2 mediastrip processing.
Add SelectedSpot, CriticalColor and ExcludeFromScoring flags to SpotColor processing.
CXF: Add XRCC_EXCLUDEFROMSCORING tag processing.
Build 3: Automation: Fix detection of spectral CGATS when manually adding substrate.
Build 2: Automation: Fix detection of spectral CGATS when manually adding channels.
Build 1: General: Bring up to 2023.9 release code base.
CCAutomationTool 2023.8
Build 2: CCJ: Output target DG values consistently.
Build 1: General: Bring up to 2023.8 release code base.
CCJ: Make JSON mapping more fault-tolerant (to copy with NaN and Inf values).
CCAutomationTool 50.2.4
Build 2: General: Remove all VS2010 dependencies.
Build 1: General: See documentation for enhancements in this release.
CCAutomationTool 50.2.2
Build 3: Automation: Fix edge case relating to DG settings from environment variables.
Build 2: CXF: Trap Out of Bounds error in PDF generation.
Build 1: General: Bring up to 5.2.2 release code base.
Improvements and New features:
- Improvement in iQC user account management and 21 CFR compliance.
- Remove all VS2010 dependencies from iControl.
- iQC geometry mismatch warning added.
- Updated the Fractional Output logic for Can Definitions
- New Lab Dip report using DE* instead of just offering a DEcmc based Lab Dip report.
- Add the ability to create Formulas with more than 6 colorants.
- User can now import multiple CxF, QTX, XML files using Import from Dropbox and assign them to the same Job Template.