Model # MOLXRAG3

ColorXRA G3 Glass Reflectance Spectrophotometer

New

For Reflectance Measurement on Glass Coatings

  • Captures non-contact specular color reflectance measurements at 3 angles to detect coating errors
  • Mounted on a traversing beam to capture measurements in cross direction
  • Connects with ESWin QC to evaluate color quality

Evaluate Color and Effectiveness of Glass Coating

Since glass is non-scattering, conventional measurement devices with direct illumination cannot provide accurate color data. The ColorXRA G3 measures from 330 nm to 1,000 nm with 1 nm optical resolution. In the lab, the device can be mounted on a stand to measure a glass pane laying on a sample support. To measure inline, the ColorXRA G3 can be mounted on a traversing beam above the pane to measure low-e glass and below the pane for the measurement of sun protection coatings.

<0.1 dE*
Repeatibility on Calibration Mirror
≤0.3 dL*, da*, db*
Inter-Instrument Agreement
> 1 second
Repetition Time
ColorXRA G3-02
Illuminates Both the UV and Visible Range

The ColorXRA G3 is a compact multi-angle spectrophotometer that measures from 330 nm to 1,000 nm with 1 nm optical resolution. It is mounted 10 mm from the glass pane and captures spectral data as well as color in reflectance on non-scattering samples at 3 different angles to qualify even multi silver layer coatings.

ColorXRA G3-03
Evaluate Color Consistency From Multiple Viewing Angles

The ColorXRA G3 uses a Xenon flash lamp to take measurements every second on non-scattering products such as coated glass using three geometries simultaneously at +15°: -15°, +45°: -45° and +60°: -60°. The ±15° measurement gives the same readings as in the laboratory with a sphere geometry measurement. The ±45° and the ±60° measurements show color change from different observer angles.

Precise Inline
Precise Inline Color Measurement

The 1 nm resolution spectra data from 330 nm to 1,000 nm provide reliable information to control the coating process.

Stability & Accuracy
Short-Term Stability and Long-Term Accuracy

Uses real dual beam measurement and automatic wavelength calibration. Only requires external calibration every 4 weeks for maximum uptime.

Operates in Harsh Environments
Operates in Harsh Production Environments

Built with durability in mind, the ColorXRA G3 is rugged enough to endure busy labs and production lines without compromising measurement accuracy.

ColorXRA G3
Specification
Design/Premedia
Formulation
Production
Quality Control

Need a Quote? Contact Sales(888) 800-9580